Decibel Meter

A decibel meter that runs in your browser on your device's microphone: live level in dB(A) or dB(Z), a one-second Leq, average since start, peak, minimum and maximum, and a sixty-second chart. It is labelled Estimated, because a browser cannot know your microphone's sensitivity; a calibration panel lets you set the offset against a reference meter or a known source, and the page states plainly how far an uncalibrated reading can be off. Exposure limits come from NIOSH and OSHA.

Result class: Estimated (uncalibrated)Press Start and allow the microphone. The meter runs in your browser; nothing is recorded or uploaded.
—dB(A)

raw— dBFS· readings can be off by 10 dB or more until you calibrate

Leq 1 s—Avg since start—Peak—Min—Max—
How accurate is this?

A browser only sees the microphone's digital signal (dBFS). Turning that into sound pressure (dB SPL) needs the microphone's sensitivity and the system's input gain, which the page cannot read. Until you calibrate, the page uses an assumed offset and the result is a rough indication, often off by 10 dB or more. Calibrate against a reference meter or a known source and the estimate follows that reference; it still depends on the microphone's response and the browser's processing staying constant.

Calibrate

Play a steady sound, read a reference meter (or a phone app you trust less than a meter), type its reading and press Set. The page sets the offset so its current 1 s level matches.

NIOSH's recommended exposure limit is 85 dB(A) averaged over 8 hours, halving the time for every 3 dB more.Decibel chart and safe exposure times

— — Hz

Runs in your browser. Nothing is uploaded.

How to use

  1. Press Start and allow the microphone. The page asks the browser to disable auto gain and noise suppression, because those compress the very levels you want to see, and reports whether it succeeded.
  2. Read the big number: the current level in dB(A) (switch to dB(Z) in Settings). Below it: the one-second Leq, the average since you started, peak, minimum and maximum, and the raw dBFS the browser actually measures.
  3. Calibrate if you can: with a steady sound playing, read a sound level meter next to your device, type its value and press Set. The card changes from "uncalibrated, assumed offset" to "calibrated by you" and the offset is remembered in this browser.
  4. Open "How accurate is this?" before quoting any figure, compare with the exposure limits below, and download the PNG report (levels, calibration state, microphone; no audio).

How to measure (steps)

Press Start and allow the microphone when the browser asks. The page requests the stream with the browser’s processing off, auto gain control, noise suppression and echo cancellation, and the Processing line confirms whether the browser honoured that; with processing on, loud sounds are pulled down and steady sounds are removed, and the readings are compressed. Keep the device still, with nothing covering the microphone, and hold a phone the way its microphone faces the sound rather than your palm. If the browser never opens a microphone, the microphone not working guide has the permission and device steps.

The big number is the current level with the weighting from Settings, dB(A) by default. Under it: the one-second Leq, the average since you pressed Start (the figure to compare with exposure limits), the peak, the minimum and maximum, and the raw dBFS the browser actually measures, which is the only number on the page that is not an estimate. The chart draws the last sixty seconds against reference lines at 40, 60, 85 and 100 dB. Reset min/max starts the statistics again without stopping; Stop releases the microphone.

The result class is Estimated, and the card says which kind: uncalibrated with an assumed offset until you calibrate, calibrated by you afterwards. The reasons are in the next section and in the “How accurate is this?” panel on the meter.

Live dB, peak and average (Leq)

Three figures describe a noise, and they answer different questions. The live level is what the sound is doing now, over the last 125 ms; it jumps with every word and door. The peak is the highest instantaneous value seen, held so you can read it; it describes impulses, a hammer blow or a slammed door, which are short enough to barely move the average but can be the loudest thing in the room. The average since start, which is the Leq over your whole measurement, is the one exposure limits are written for: the steady level that would carry the same energy as everything you measured. A room with a 50 dB(A) average and 85 dB(A) peaks is a quiet room with occasional bangs; a room with an 80 dB(A) average is loud all the time even if nothing in it is startling.

The meter computes level from the RMS of the raw samples, converts to dBFS, adds the offset to express it as dB SPL, and applies the weighting on the signal’s spectrum. Leq is energy-averaged, not arithmetically averaged, which is why one loud minute moves an hour’s average more than intuition suggests.

How accurate is a browser decibel meter?

A browser receives the microphone’s signal as numbers between −1 and +1, full scale. It does not receive the microphone’s sensitivity (how many of those units a given sound pressure produces), the input gain the operating system applies, or anything about the microphone’s frequency response. The conversion from the dBFS the page measures to the dB SPL you want is therefore a single unknown offset, and before calibration the page can only assume one. The assumed value is typical for a laptop microphone at default gain and is stated on the card as an assumption; on a different device or gain it can be 10 dB or more off, in either direction, which is the difference between a quiet office and a busy street.

Calibration replaces the assumption with a measurement: you tell the page what a reference meter reads at the same moment, it sets the offset so its one-second level matches, and from then on it tracks changes relative to that reference. That is a usable estimate for comparing rooms, times of day or settings, and it stays valid only as long as the microphone, the input gain and the browser’s processing stay the same; changing any of them, including letting the operating system auto-adjust the input volume, shifts the offset again. Two further limits remain after calibration: a consumer microphone is not flat across frequencies, so a reading calibrated with speech can be off for bass-heavy noise, and it compresses or clips at high levels, so readings above roughly 100 dB are unreliable on most built-in microphones.

For those reasons the page never calls itself a sound level meter in the instrument sense. Meters used for regulations meet IEC 61672 performance classes and are calibrated with an acoustic calibrator before use; a browser can do neither. Use this page to get an idea, to compare, and to decide whether a real measurement is worth arranging.

Calibrate against a known source

Two ways, from better to worse. Against a reference meter: play or find a steady sound, a fan, a noise track from the tone generator, held at a constant level; put the reference meter beside your device’s microphone; read it; type the reading into the Reference box and press Set. The page adjusts the offset so its current one-second level equals your reading and marks the result as calibrated by you. Repeat at a second level if you can (quiet and loud); if the two offsets differ by more than a couple of dB, the microphone or the browser is compressing and the estimate is only good near the level you calibrated at.

Against a known source: without a meter, the honest choice is a device whose level is documented by its maker under stated conditions, which is rare. Common suggestions such as “normal conversation is 60 dB” are ranges, not references, and calibrating to them produces an estimate with the uncertainty of the range built in. If that is all you have, say so when you quote a figure, and prefer comparisons (before and after, room A versus room B) over absolute numbers.

The offset is stored in your browser’s local storage for this device and can be edited directly in Settings or cleared with Reset; the raw dBFS figure under the big number lets you check the arithmetic yourself.

dB(A), dB(C) and dB(Z)

Weighting curves adjust a measurement for how the ear hears. A-weighting follows the ear’s reduced sensitivity to low and very high frequencies at moderate levels; it is the curve written into NIOSH’s and OSHA’s limits and the one almost every published level uses, so the meter defaults to it. The page applies the IEC 61672-1 A-curve to the signal’s spectrum bin by bin, which is equivalent to the filter a meter uses and needs no coefficient tables; the curve was checked against the octave-band A-weighting corrections published in 40 CFR § 211.207. Z-weighting is no weighting: the raw level, which counts bass, rumble and traffic in full and reads higher for anything with low-frequency content. C-weighting sits between the two, nearly flat across the audible range with gentle roll-offs at the extremes, and is used for peak measurements and for judging low-frequency noise such as music; it is not offered here because its distinct use, peak levels of impulsive noise, is exactly where a consumer microphone is least trustworthy, and offering it would suggest a precision the page does not have. The difference between the A and Z readings of the same sound tells you how much of it is low frequency.

Common sound levels

The table gives the reference points that NIOSH publishes on its noise page, with the equipment it names at each, and OSHA’s permissible-exposure anchor. It is deliberately short; the decibel chart guide carries the full table with every row sourced.

LevelWhat NIOSH and OSHA sayExamples NIOSH names
85 dB(A)NIOSH recommended exposure limit, averaged over an 8-hour workday; “often require you to raise your voice to be heard by someone 3 feet away”printing presses, lawn mowers, vacuums, power tools
90 dB(A)OSHA permissible exposure limit for 8 hours (Table G-16)—
95 dB(A) and above“you likely have to shout to be heard by someone 3 feet away”bulldozers, ambulance sirens, chain saws, bars/nightclubs, large sporting events

CDC’s Vital Signs infographic “Too Loud! For Too Long!” (2017) adds everyday anchors with the time after which it says damage can occur: washing machine 70 dB; traffic noise inside a car 80 dB; leaf blower 90 dB, 2 hours; sporting event 100 dB, 14 minutes; rock concert 110 dB, 2 minutes; siren 120 dB, 1 minute, and states that “85dB is the approximate point at which extended exposure can cause hearing damage.”

Sources: NIOSH, Noise-Induced Hearing Loss; OSHA 29 CFR 1910.95; CDC Vital Signs, Too Loud! For Too Long!.

Safe exposure limits (NIOSH/OSHA sourced)

NIOSH recommends an exposure limit of 85 dB(A) averaged over an eight-hour workday and, in its words, “for each 3 dBA increase in noise level, NIOSH recommends reducing the exposure duration by half.” Applying that rule gives 4 hours at 88 dB(A), 2 hours at 91, 1 hour at 94, 30 minutes at 97 and 15 minutes at 100 dB(A); those durations follow arithmetically from the published rule and are the ones NIOSH’s criteria document tabulates.

OSHA’s workplace standard (29 CFR 1910.95) sets permissible exposures in Table G-16: 8 hours at 90 dB(A), 6 hours at 92, 4 hours at 95, 3 hours at 97, 2 hours at 100, 1½ hours at 102, 1 hour at 105, ½ hour at 110 and ¼ hour or less at 115 dB(A), a 5 dB exchange rate, with an action level of an 8-hour time-weighted average of 85 dB(A) at which a hearing conservation programme is required. OSHA’s figures are legal minimums for US workplaces; NIOSH’s are health recommendations and are stricter.

The two sets exist for different purposes and disagree above 85 dB(A); the decibel chart guide lays them side by side. Neither says anything about a single reading from a browser meter: the limits are averages over a working day, measured with instruments that meet a standard. What the meter here can do is tell you whether a room is in the neighbourhood of those averages, and whether a change you made moved it.

Measuring a room, a street or a machine

Where you hold the microphone matters as much as the microphone. For a room, measure at the position where people are, at head height, away from walls and corners, which reinforce low frequencies and read high; for a machine, measure at the operator’s ear position rather than next to the casing; for traffic or neighbours, measure at the window you would normally have open, and note whether it was open. Let the meter run for at least a minute so the average settles, longer if the noise comes and goes, and reset the statistics when you move. Wind across a microphone reads as loud low-frequency noise; outdoors, shield it with your body or a foam cover, or switch to dB(A), which discounts most of it.

Laptop and phone microphones differ in where they point and what they ignore. A laptop’s array sits by the keyboard or the screen hinge and hears the fan and the keys first; put the laptop on a soft surface and don’t type while measuring. A phone’s main microphone is at the bottom edge, so point that edge toward the sound and keep your fingers off it; phones in a case with a covered port read several dB low. Bluetooth headsets are not suitable at all, since they switch to a narrow-band voice profile with its own automatic gain, and their readings bear no stable relation to the sound in the room.

Comparisons are where an uncalibrated meter is still genuinely useful, every time. The difference between two readings taken with the same device, same gain and same weighting is far more reliable than either reading alone, because the unknown offset cancels: a fan that reads 8 dB above the room with it off is 8 dB above the room whatever the absolute figures are. Use that for before-and-after checks, for finding the quietest corner of an office or for showing that a setting change made a difference, and leave absolute claims to a calibrated instrument.

Save a report

The PNG report records the average since start, minimum, maximum and peak with the weighting, the calibration state and offset, the microphone the browser used and whether its processing was off, the date and this page’s address. It does not contain audio. Use it to keep a note of a measurement or to show someone what you saw; for anything with consequences, a noise complaint, a workplace assessment, a tenancy dispute, arrange a measurement with a class-compliant meter and quote that instead. The report says so on its last line.

Frequently asked questions

How accurate is an online decibel meter?

Uncalibrated, not very: a browser only sees the microphone's digital signal, not its sensitivity or the system's input gain, so the page assumes an offset and readings can be off by 10 dB or more either way. Calibrated against a real sound level meter, a laptop or phone microphone tracks changes within a few dB over the middle of the range, but it remains an estimate from a consumer microphone, not an instrument.

What does dB(A) mean?

A-weighting adjusts the measured level for the ear's sensitivity, counting low and very high frequencies for less than the mid-range where speech sits. Workplace limits (NIOSH, OSHA) are written in dB(A), so the meter defaults to it. dB(Z) is the unweighted level, which counts bass and rumble in full and reads higher for traffic, music and machinery.

What is a safe decibel level?

NIOSH recommends keeping average exposure to 85 dB(A) or less over an eight-hour day and halving the allowed time for every 3 dB above that; OSHA's workplace limit is 90 dB(A) over eight hours with action required from 85. Everyday levels below those figures are not harmful by duration alone, and no single reading on a browser meter should be used to decide that something is safe or unsafe.

Why does the meter read differently from my phone app?

Each is estimating with a different microphone, a different assumed sensitivity and different processing; two uncalibrated estimates rarely agree. Calibrate both against the same reference and they converge. The phone app may also apply its own calibration profile for that phone model, which is why dedicated apps on known hardware are usually closer than a browser on an unknown microphone.

Can I use this decibel meter for a noise complaint or at work?

As an indication to decide whether a proper measurement is worth arranging, yes; as evidence, no. Noise regulations specify meters that meet a standard (IEC 61672 classes) and calibration procedures a browser cannot satisfy. Note the reading, the time and the calibration state in the report, then measure with a class-compliant meter.

Does the decibel meter record or upload sound?

No. The level is computed from the live stream in your browser; no audio is stored or sent. The calibration offset you set is saved in your browser's local storage so it is there next time, and you can clear it with Reset.

Why does the meter ask to turn off auto gain and noise suppression?

Auto gain raises quiet sounds and lowers loud ones, which flattens exactly the differences a meter exists to show, and noise suppression removes steady sounds such as fans and traffic, which are often the noise you are trying to measure. The page requests both off; if the browser refuses, the Processing line says so and readings are compressed.

What is Leq?

The equivalent continuous level: the steady level that would carry the same energy as the fluctuating sound over the period. The one-second Leq smooths the instant readings; the average since start is the Leq over your whole measurement, which is the figure exposure limits are written for.

Last updated:

Reviewed by: TestPane Editorial Team

Tested on: Firefox 142 (automated, fake microphone device)