Decibel Chart – How Loud Common Sounds Are, With Safe Limits
A decibel chart is only as good as where its numbers come from, and most charts online copy each other. This one lists only figures published by NIOSH (the US National Institute for Occupational Safety and Health, part of CDC), by CDC’s Vital Signs programme, or in OSHA’s noise regulation, with the source beside each row, and it leaves out the rows those sources don’t give. Below the chart: the safe exposure time at each level under the NIOSH and OSHA rules, a mini version of the decibel meter so you can compare your own room with the same Estimated label the full tool uses, and why charts disagree with each other. This is not a medical test and nothing here is medical advice; the figures are occupational and public-health reference points.
The decibel scale in plain words
A decibel is a ratio on a logarithmic scale, not a quantity like a metre. Every 10 dB is ten times the sound energy, and every 3 dB is double; 20 dB more is a hundred times the energy. The ear doesn’t hear it that way: a 10 dB step sounds roughly “twice as loud”, which is why a chart from 0 to 140 covers a range of a hundred trillion to one in energy and still reads as a sensible ladder. Zero is set near the quietest sound a young, healthy ear can detect at the frequencies it hears best; negative values exist but are rare outside laboratories.
The letter after dB matters. dB(A) means the measurement is A-weighted: low and very high frequencies are discounted to match how the ear responds at moderate levels, and all the occupational limits are written this way. dB(C) is nearly flat and used for peaks and low-frequency noise; dB(Z) is unweighted. The same sound reads higher in dB(C) or dB(Z) than in dB(A) when it has bass in it. Charts that mix the weightings, or don’t say which they use, are part of why they disagree.
Two more things that trip people up. Level depends on distance: the figures below are at the listener’s position the source states (or, for the equipment lists, at the operator), and a lawn mower across the street is far quieter than one you are pushing. And duration matters as much as level: the limits in the next sections are averages over a day, and a brief loud sound and a long moderate one can carry the same dose.
Decibel chart: common sounds from 0 to 140 dB
Every row names its source. Rows marked NIOSH come from NIOSH’s Noise-Induced Hearing Loss page; rows marked CDC from the CDC Vital Signs infographic “Too Loud! For Too Long!” (2017); the OSHA row from 29 CFR 1910.95. Levels are approximate by nature and the sources give them as typical values, not measurements of a particular device.
| Level, dB(A) | Sound or situation | What the source says | Source |
|---|---|---|---|
| 70 | Washing machine | listed as an everyday level | CDC Vital Signs |
| 80 | Traffic noise inside a car | listed as an everyday level | CDC Vital Signs |
| 85 | Printing presses, lawn mowers, vacuums, power tools | NIOSH recommended exposure limit, averaged over an 8-hour workday; sounds at this level “often require you to raise your voice to be heard by someone 3 feet away”; CDC: “85dB is the approximate point at which extended exposure can cause hearing damage” | NIOSH, CDC Vital Signs |
| 90 | Leaf blower | CDC: 2 hours can cause damage; OSHA permissible exposure limit for 8 hours | CDC Vital Signs, OSHA 1910.95 |
| 95 and above | Bulldozers, ambulance sirens, chain saws, bars/nightclubs, large sporting events | “you likely have to shout to be heard by someone 3 feet away” | NIOSH |
| 100 | Sporting event | CDC: 14 minutes can cause damage | CDC Vital Signs |
| 110 | Rock concert | CDC: 2 minutes can cause damage | CDC Vital Signs |
| 115 | — | OSHA: ¼ hour or less per day, the top row of Table G-16 | OSHA 1910.95 |
| 120 | Siren | CDC: 1 minute can cause damage | CDC Vital Signs |
Rows you may expect and will not find here, such as a figure for a whisper, normal conversation or a jet engine, are missing because the three sources above do not give them; other charts take them from textbooks or from each other. The chart stops at 120 because that is the highest figure the sources attach to a named sound; the scale continues to the threshold of pain and beyond, and the sources treat anything at that level as an immediate hazard rather than a duration question.
Safe exposure time by level
Two rules are in use in the United States and they disagree above 85 dB(A).
NIOSH recommended exposure limit (REL). 85 dB(A) averaged over an eight-hour workday, with a 3 dB exchange rate: “for each 3 dBA increase in noise level, NIOSH recommends reducing the exposure duration by half.” Applied step by step that gives 8 hours at 85 dB(A), 4 hours at 88, 2 hours at 91, 1 hour at 94, 30 minutes at 97 and 15 minutes at 100 dB(A); the durations are the arithmetic consequence of the published rule and match the table in NIOSH’s criteria document. NIOSH’s figures are health-based recommendations.
OSHA permissible exposure limit (PEL). The legal limit for US general-industry workplaces in 29 CFR 1910.95, Table G-16: 8 hours at 90 dB(A), 6 hours at 92, 4 hours at 95, 3 hours at 97, 2 hours at 100, 1½ hours at 102, 1 hour at 105, ½ hour at 110 and ¼ hour or less at 115 dB(A), a 5 dB exchange rate. OSHA also sets an action level of an 8-hour time-weighted average of 85 dB(A), at which employers must run a hearing conservation programme.
The gap is the exchange rate. Halving the time every 3 dB follows the physics of sound energy (3 dB is a doubling); the 5 dB rule was a regulatory compromise that assumes intermittent exposure is less harmful than continuous. For your own listening, the NIOSH figures are the conservative ones and the ones public-health bodies quote. Remember that both are daily averages: a 100 dB(A) concert for two hours and a quiet day otherwise is a dose, not a single number, and CDC’s “can cause damage” times above are its own simplification of the same idea for the public.
Measure your own room
The box below is a small version of the decibel meter. Press the button, allow the microphone, and it estimates the level for fifteen seconds and gives an average. The number is Estimated: a browser cannot know your microphone’s sensitivity, so without calibration the page assumes an offset and the figure can be 10 dB or more off in either direction. If you have calibrated the full meter in this browser, the mini meter uses that offset and says so.
Asks for the microphone when you press the button; nothing is recorded. The figure is an estimate with an assumed offset until the full meter is calibrated.
Open the full decibel meter to calibrate and keep a reportUse it the way the limitations allow: to see whether your room sits nearer 40 or 70, to compare the same place at two times of day, to check whether closing a window or moving a fan changed anything. For a figure you would quote, calibrate the full meter against a reference, and for anything with consequences, a complaint, a workplace, a tenancy, measure with a sound level meter that meets IEC 61672 and quote that. The meter page explains the calibration and what it does and does not fix.
Reading the chart in everyday life
The chart is written for workplaces, but the same rows map onto ordinary days. Household appliances sit at the bottom of the hazardous range or below it: CDC’s washing machine at 70 dB(A) is a sound you can talk over without effort, and a dishwasher or a kitchen extractor is in the same neighbourhood. Powered garden and workshop tools are where the limits start to matter: NIOSH lists lawn mowers and power tools at 85 dB(A), the level at which you have to raise your voice to someone an arm’s length away, and CDC puts a leaf blower at 90 dB(A) with two hours before damage can occur. An afternoon of mowing, trimming and blowing is a workplace dose, which is why the people who do it for a living wear protection and why the same protection makes sense at home.
Traffic is the common case that sits just under the line: CDC’s 80 dB(A) inside a car is a long way from quiet but below the eight-hour limit, and the risk from it comes from hours rather than from any moment. Entertainment is the common case above it: CDC’s sporting event at 100 dB(A), rock concert at 110 and siren at 120 carry minutes, not hours, and NIOSH names bars and nightclubs alongside chain saws and ambulance sirens in its 95-and-above group. A loud venue is not dangerous because of a single song; it is the three hours, and the rule of thumb from NIOSH’s own description holds: if you have to shout to be heard by someone three feet away, you are at or above 95 dB(A), and the clock is short.
What the chart cannot tell you is your own exposure, which depends on distance, time and what else the day contained; that is what the meter below and the full decibel meter are for, with the honesty that a browser’s number is an estimate.
Headphones and earbuds
Headphones are the exposure most people never measure, because the sound happens inside the ear and no meter in the room sees it. The same rules apply: a listening level that would be a loud room is a loud room for the ear, and time adds up across the day. There is no way to measure headphone level with a browser or a phone’s microphone, and this site does not pretend to; what you can do is use the headphone test to set a comfortable level with a reference tone and keep it, prefer the listening-level limiter that phones and music apps offer, and treat the NIOSH rule as the budget: the louder the setting, the shorter the day’s listening. Signs that a level is too high are the same as for any noise: ringing or muffled hearing after taking the headphones off, having to raise the volume as the day goes on, and not hearing a person who speaks to you at normal volume while you listen.
dB(A) and why charts disagree
Two decibel charts that both look authoritative can differ by 10 or 20 dB on the same row, for four reasons that are worth recognising. Weighting: one chart’s figure is dB(A), the other’s dB(C) or unweighted, and the difference is largest for sounds with bass. Distance: “lawn mower” at the operator’s ear and at the neighbour’s window are different sounds; few charts state the distance. Copying: most consumer charts are compiled from other charts, and a rounded figure from a 1970s textbook survives decades of copying as if it were a measurement. Purpose: occupational sources quote levels at which workers need protection; product and marketing sources quote the quietest configuration. The three sources behind this page share a purpose and a weighting, which is why their figures fit together, and the rows they don’t give are left empty rather than filled from elsewhere.
When you see a chart figure that matters to you, check three things: the weighting, the distance, and whether a primary source is named. If none is, treat the number as an illustration rather than a measurement.
FAQ
How many decibels is too loud? The sources draw the line for extended exposure at 85 dB(A) averaged over eight hours (NIOSH; CDC calls it “the approximate point at which extended exposure can cause hearing damage”), with less time allowed as the level rises. A single short sound below the levels where CDC quotes minutes is not harmful by duration; the risk is the daily dose.
What is the decibel level of normal conversation? The three sources this chart relies on do not give a figure for conversation, so it is not listed; the closest sourced anchor is NIOSH’s description that at 85 dB(A) you have to raise your voice to be heard three feet away.
How long can I listen at 100 dB? NIOSH’s rule gives 15 minutes per day; OSHA’s table allows 2 hours; CDC’s public figure for a 100 dB sporting event is 14 minutes before damage can occur. The disagreement is the exchange rate, explained above; the conservative figure is NIOSH’s.
Can I measure decibels with my phone or laptop? You can estimate them. A browser or an app sees only the microphone’s digital signal, not its sensitivity, so readings are estimates until calibrated against a reference meter, and even then the microphone’s response limits them. The meter on this site says Estimated on every reading for that reason.
What does dB(A) mean on a chart? That the figures are A-weighted: adjusted for the ear’s sensitivity by discounting low and very high frequencies. Occupational limits are written in dB(A). A chart that doesn’t say which weighting it uses can’t be compared reliably with one that does.
Why does this chart have no row for a whisper, a library or a jet? Because the three sources it relies on do not publish those figures, and the chart does not borrow from others. Charts that have them are usually quoting textbook illustrations; the levels are plausible but untraceable, and this page would rather leave a gap than present a copied number as a source.
Do the limits apply to children? The occupational figures are written for adult workers. Public-health bodies treat children’s hearing as at least as vulnerable and advise lower exposures for recreational sound, and the general principle, less time at higher levels, applies the same way; this page gives no child-specific numbers because its sources don’t.
Is a 10 dB increase twice as loud? It is ten times the sound energy and is perceived as roughly twice as loud, which is the difference between physics and hearing. A 3 dB increase doubles the energy and is barely noticeable; that is why the exposure rules halve the allowed time per 3 dB (NIOSH) rather than per “twice as loud”.